Mini Load Calculator

Device Name

AC or DC Load

Wattage

Running Time

Days/Week

DC Daily Load

Losses

W

Hrs/Day

Wh

Losses

Total DC Loads

Inverter Rated Power (VA)

<<< Enter Inverter Rated Continous Power

Inverter Losses

<<< Inverter losses can be changed, although 20% is often used.

Inverter Quiescent (W)

<<< Adjust to suit model of inverter.

Inverter Running Hours

<<< Make sure AC running time is covered.

Inverter Power Draw

Wh / Day

© solar-wind.co.uk

Mini Off-Grid Power System Calculator

Average daily load (DC) from Loads Sheet 1

(Wh)

Total Daily Load Inc Wiring Losses (DC)

(Wh)

Number of days required in batteries

Days

<<<Enter days of battery autonomy – usually between 4 and 14,

Wh of storage required

Wh

depends on how critical the system is and the availability of back-up sources.

kWh of storage required

kWh

Voltage of battery bank

VDC

<<<Select desired battery voltage – often 12V for small systems, 24V for medium and 48V for large.

Ah capacity of battery bank

Ah

For boats & vehicles, it often makes sense to match the battery bank voltage to the alternator voltage.

Number of sunlight hours (worst month)

hrs

<<<In UK, in mid-winter, this ranges from 1hr in the far south, to 0.5hrs in Scotland. Depends on latitude.

Sunlight Intensity

W/m2

In the summer, the average is about 4x the winter hours (in the UK).

Minimum wattage of solar pv array

Wp

In Spain, the mid-winter figure is more like 2hrs, with 5hrs in the summer.

Suggested MPPT Controller Current Rating

A

Meteo Deviations

Allowance for weather deviations

<<<This figure allows for deviations from the average meteo data, which can on occasion reach 40%.

The more critical the power system, the higher this figure needs to be.

Losses

Cable / Fuse / MCB Losses

<<< Standard losses – can be adjusted.

Battery losses

<<< Gel or AGM batteries are often 90% or higher efficiency. Wet / flooded batteries are lower, often 75-80%

© solar-wind.co.uk

Cable Sizing Calculator

Distance (m)

Current (A)

Watts

Voltage

Losses (%)

Cable Size (mm2)

Rounded Up Cable Size Current Rated

Cable Size Max Current

Solar PV Array to Controller

mm^2

A

Controller to Battery Bank

mm^2

A

Battery Interconnects

mm^2

A

Inverter DC Cables

mm^2

A

Other Cable X (All Manual Entry)

mm^2

A

Other Cable Y (All Manual Entry)

mm^2

A

Other Cable Z (All Manual Entry)

mm^2

A

Inverter Wattage Rating

W

<<< Taken from load calculator sheet.

Inverter Current (Cont)

A

Mains Charger

A

<<<Enter current rating of mains charger (to add to overall charge current).

Total Charge Current (Mains + PV)

A

Larger of charge / discharge currents

A

SortOrder– This is an optional parameter

Enter 0 or FALSE if the first column in the Array (against which you are performing the search) is not sorted

Peak DC Current (Charge or Discharge)

A

Selected Controller Current

A

Solar Controller Current (Suggested Min)

A

<<< Suggested minimum current rating of MPPT controller.

Solar Controller Voltage Rating (Min)

Voc

<<<Ensure Charge Controller has higher max pv input voltage than this.

Controller Current (Manual Input)

A

<<< Enter current rating of chosen charge controller.

Solar PV Array – Minimum Power

Wp

Solar PV Panel – Rated Wattage

Wp

<<<Enter Power in Watts of chosen solar pv panel.

Number of pv panels in parallel

<<< Enter number of pv panels to be wired in parallel up to controller current limit

Number of series strings of panels

<<< Enter number of pv panels to be wired in series up to controller voltage limit

Solar PV Panel Voltage (Vmp)

Vmp

<<<Enter Voltage Max Power (Vmp) of chosen solar pv panel.

Solar PV Panel Voltage

Voc

<<< Enter Voltage Open Circuit (Voc) of chosen solar pv panel.

Solar PV Array Voltage (Vmp)

Vmp

Chosen Solar PV Array Power (W)

Wp

© solar-wind.co.uk

0

0

300

120

Solar PV Module

Voc

Vmp

Wp

Current

Datasheet Link

Victron 30 Wp

30

Victron 50Wp

50

Victron 70 Wp

70

Victron 100 Wp

100

Ulica 100 Wp

100

Ulica 150 Wp

150

Ulica 200 Wp

200

Panasonic HIT 245 Wp

245

Jinko Maxim 270 Wp

270

Jinko Maxim 300 Wp

300

Canadian Solar Mono Perc 330 Wp

330

LG Mono 340 Wp

340

LG Mono 365 Wp

365